This compact instrument has been designed specifically
to demonstrate and test POU reverse osmosis or distillation
systems. By measuring electrical conductivity, it will quickly
determine the parts per million/Total Dissolved Solids (ppm/TDS)
of any drinking water. With a single "before and after"
test, this handy device effectively demonstrates how your
RO or distillation system eliminates harmful dissolved solids.
It will also service test systems, including membrane evaluation
programs.
RO
Meters
|
Features
|
|
Instant and accurate TDS tests |
|
Electronic Internal Standard for easy field calibration |
|
Fast Automatic Temperature Compensation
|
|
Rugged design for years of trouble free testing
|
|
Simple to use
|
The Myron L RO-1 Meter is easy to use and requires no special training. Simply pour the sample into the permanent cell cup and press the rubber-protected button. ppm/TDS is immediately indicated on the color-coded scale (models without the color band dial are also available). No temperature adjustments are ever required!
Model RO-1 (Shown with optional case)
|

These instruments are engineered for maximum accuracy and reliability. Precision readings are indicated on the 50-division scale with repeatability to ± 1%. Each instrument is individually tested, inspected, and calibrated at the Myron L factory to ensure accuracy and long life. All three models are supplied with a standard 9 volt battery that will last over 2,000 readings, or approximately 1 year.
Model RO-1NC
|
Accessories
|
|
Standard Solutions are used to periodically recalibrate instruments for greatest accuracy. Model 442-1000 (1000 ppm/TDS) is the type used in Myron L factory calibrations. |
|
|
Porta-Pak Carrying Case
For use with all Myron L DS and pDS portable instruments. Foam lined and molded of sturdy ABS plastic. Model PTP
Solutions and vials not included in Porta Pak.
|
|
|
If You Also Test pH, see ULTRAMETER™, TECHPRO, or pDS Meters
|
|
|
Automatic Temperature Compensation
Why It's Important
Conductivity readings change with temperature; TDS does not change. Some instruments ignore the importance of temperature. Others require a separate thermometer for testing sample temperature, then manual adjustment of the instrument. All Myron L instruments, however, feature fast and precise Automatic Temperature Compensation. The result: a more accurate, useful instrument. |
|
Instrument Specifications
|
|
Ranges
|
|
Model RO-1:
|
0-1250 ppm
|
|
|
(0-250 blue, 250-500 orange, 500-1250 red)
|
|
Model RO-1NC:
|
0-1250 ppm (no color band)
|
|
Model DS-1:
|
same as RO-1NC
|
|
|
Temperature Compensation
|
Automatic (to 25ºC/77ºF) between 50º and 160ºF (10-71ºC)
|
|
Cell Cup
|
Chip and crack resistant polyethylene
|
|
Electrodes
|
Built-in, never need replatinizing
|
|
Accuracy
|
±2% full scale
|
|
Repeatability
|
±1%
|
|
Recalibration
|
Internal electronic standard quickly verifies on-site accuracy
|
|
Circuitry
|
Solid-state, sealed against moisture
|
|
Batteries
|
One 9-volt (supplied), good for 2,000 tests/1 year
|
|
Dimensions
|
3.4"W x 4.5"D x 4.0"H (85 x 129 x 126 mm)
|
|
Weight
|
Less than one pound (.45 kg)
|
|